Test and Measurement
The HF series shunts provide an accurate current sensing solution for many wideband power measurement applications up to 500Arms, the shunts are supplied with a 2m safety BNC lead.
Utilising an innovative design unique to N4L that exhibits exceptionally low parasitic inductance, each shunt will maintain its specified resistance over a frequency range from DC to 1MHz without exhibiting the phase shift that is normally associated with high current resistive shunts.
While the HF series was primarily designed for use with the PPA series power analyzers from N4L that provide exceptional wideband accuracy, dynamic range and common mode rejection, the HF series can be used as a precise current sensing device for other equipment.
Model |
Nominal Resistance |
Continuous Current |
PPA typical min Current |
Input Connector |
HF500 |
0.2mΩ |
500Arms |
0.5Arms |
M16 bolt/lug |
HF200 |
0.5mΩ |
200Arms |
0.2Arms |
M10 bolt |
HF100 |
1mΩ |
100Arms |
0.1Arms |
M10 bolt |
HF020 |
10mΩ |
20Arms |
10mArms |
4mm socket |
HF006 |
100mΩ |
6Arms |
1mArms |
4mm socket |
HF003 |
470mΩ |
3Arms |
0.2mArms |
4mm socket |
HF01A |
1Ω |
1.5Arms |
0.1mArms |
4mm socket |
High Frequency Rogowski Current Transducers
AC sensing Rogowski current transducer designed for use with the PPA range Precision Power Analyser, enabling high frequency high accuracy current measurement.
Model |
Measuring range |
Frequency Range |
Output Signal |
oSpecificationo Data |
WR5000 |
1A to 5kA |
1Hz to 1MHz |
1A=2mV/0.4mV |
![]() |
WR10000 |
100kW / 125 kVA |
0-120V L-N / 208V L-L |
350Arms / Phase |
![]() |
LEM High Accuracy Zero Flux Current Transducers
For ultra-high precision measurement of current: DC,AC,pulsed…, with galvanic separation between primary and secondary.
Features:
- Closed loop (compensated) current transducer using an extremely accurate zero flux detector.
- Electrostatic shield between primary and secondary circuit
- 9-pin D-Sub male secondary connector
- Optically insulated output (photocoupler type) indicates transducer state
- LED indicator confirms normal operation.
Danisense High Accuracy Zero Flux Current Transducers
The Danisense range of Zero flux current measurement transducers, these current sensors based upon the Zero Flux measurement technique provide high accuracy current measurement up to 2,000Arms
Model |
Current Rating |
Specification Data |
Danisense DS200
|
→ 200Arms | ![]() |
Danisense DS600
|
→ 600Arms | ![]() |
Danisense DS2000
|
→ 2000Arms | ![]() |
Danisense DSSIU-4
|
4 Channel Interface Unit |
![]() |
AC+DC Current Clamps
Our AC+DC Current Clamp range provide current measurement up to 5,000A (P50-3C) with an upper bandwidth of 5kHz (SC3C), these current clamps offer a convenient method of measurement for applications where the DC component of a signal is of particular interest. For example, these clamps are ideally suited to measurement of the DC bus in an inverter drive.
Model | Current Rating | Specification Data |
SC-2C-100 |
1 → 100A | ![]() |
SC-3C-1000 |
1 → 1000A | ![]() |
P20-3C-2000 |
40 → 1000/2000A | ![]() |
P40-3C-4000 |
40 → 2000/4000A | ![]() |
P50-3C-5000 |
50 → 2000/5000A | ![]() |
AC Current Clamps
Our AC Current Clamp range provide current measurement up to 3,000A (P32-UE) with an upper bandwidth of 15kHz (SMUB), these current clamps offer an accurate measurement of an AC signal over a wide bandwidth. Typical applications include PWM Invert Driver output power measurement, transformer loss testing and a range of other AC applications. The wideband response of these current clamps is very flat well beyond the stated frequency range, these AC current clamps offer an ideal solution where cost and convenience must be accompanied with sufficient accuracy.