PS 1000 High Power Series Switched-mode DC Power Supplies
DC Power Supplies, EA-PS 1000 Series
The EA-PS 1000 series is a range of adjustable, heavy-duty, switched-mode DC power supplies offering standard output volt- ages of up to 900V , output currents of up to 6000A and output power ratings of up to 120kW (output voltage/current/power of up to 1000V/40000A/800kW upon request) This series is used in high-power environments such as electroplating (e.g. surface treatment, water purification), multiple industrial applications such as powering of electric engine starters, DC motors etc. and is used in automatic end-of-line test systems for the testing of contactors, relays, switches, breakers and heavy duty DC components in general.
All units can be remotely controlled and read back via 0…10V, e.g. via a PLC. Depending on the model, they are equipped with 10-turn potentiometers for voltage and current adjustment and volt- and ampere meters. Furthermore, all models can be controlled via the optional, external and comfortable user panel EA-PS 280.
All units are protected against overload and short-circuit and can be equipped with remote sensing and computer interface (RS232/RS485) as an option. An Ethernet interface (LAN) is available upon request as well. All units have a 3x 400V, 50-60Hz mains input.
DC Power Supplies EA-PS 1000 5000W – 120000W
Key Features
High efficiency >85%
Output power ratings: 5kW up to 120kW
Output voltages: 0…20V up to 0…900V
Output currents: 0…3 A up to 0…6000A
Regulation deviation <2%
Ripple (300 Hz) <2% Constant voltage and current regulation Voltage and current adjustable 0…100% Meters for voltage and current U / I
programmable via 0…10V U / I monitoring via 0…10V Remote ?on/off“ for DC output Mains supply 3x 400V AC , power factor >0.95
Inrush current limit
DC output connector via copper bars
Options
Programming via PC (RS485 / RS232 / LAN)
Insulated analogue amplifiers
Remote sensing
Regulation deviation <1%
Ripple (300 Hz) <1% PS 1000-6KW 2700W – 6000W Key Features: High efficiency >85%
Output power ratings: 2700W up to 6000W
Output voltages: 0…20V up to 0…900V
Output currents: 0…3A up to 0…250A
Constant voltage and current regulation
3-digit LED display for voltage and current
U / I programmable via 0…10V
U / I monitoring via 0…10V
Remote ?on/off“ for DC output
Operation temp range 0-35°C (40°C on req.)
Mains input 3 x 400V +/-10% 50-60Hz, P.F. >0,95
Inrush current limit
Air cooling by fan, air volume req. max. 360m3/h
Stainless steel housing, for 19“ rack systems
DC output connector via copper bars
Options
Programming via PC (RS485/RS232/LAN)
Insulated analogue amplifiers
Remote sensing
Regulation deviation <1%
Ripple (300 Hz) <1%
DC Power Supplies EA-PS 1000 5000W – 120000W
Key Features
High efficiency >85%
Output power ratings: 5kW up to 120kW
Output voltages: 0…20V up to 0…900V
Output currents: 0…3 A up to 0…6000A
Regulation deviation <2%
Ripple (300 Hz) <2%
Constant voltage and current regulation
Voltage and current adjustable 0…100%
Meters for voltage and current
U / I programmable via 0…10V
U / I monitoring via 0…10V
Remote ?on/off“ for DC output
Mains supply 3x 400V AC, power factor >0.95
Inrush current limit
DC output connector via copper bars
Options
Programming via PC (RS485 / RS232 / LAN)
Insulated analog amplifiers
Remote sensing
Regulation deviation <1%
Ripple (300 Hz) <1%
DC Power Supplies PS 1000-6KW 2700W – 6000W
Key Features
High efficiency >85%
Output power ratings: 2700W up to 6000W
Output voltages: 0…20V up to 0…900V
Output currents: 0…3A up to 0…250A
Constant voltage and current regulation
3-digit LED display for voltage and current
U / I programmable via 0…10V
U / I monitoring via 0…10V
Remote ?on/off“ for DC output
Operation temp range 0-35°C (40°C on req.)
Mains input 3 x 400V +/-10% 50-60Hz, P.F. >0,95
Inrush current limit
Air cooling by fan, air volume req. max. 360m3/h
Stainless steel housing, for 19“ rack systems
DC output connector via copper bars
Options
Programming via PC (RS485/RS232/LAN)
Insulated analogue amplifiers
Remote sensing
Regulation deviation <1%
Ripple (300 Hz) <1%
Model
Voltage (V)
Current (A)
Power (W)
EA-PS 1020-250
0-20
0-250
0-5000
EA-PS 1040-150
0-40
0-150
0-6000
EA-PS 1060-100
0-60
0-100
0-6000
EA-PS 1080-60
0-80
0-60
0-4800
EA-PS 1150-40
0-150
0-40
0-6000
EA-PS 1300-20
0-300
0-20
0-6000
EA-PS 1600-10
0-600
0-10
0-6000
EA-PS 1900-3
0-900
0-3
0-2700
DC Power Supplies PS 1000-15KW 14000W – 18000W
Key Features
High efficiency >85%
Output power ratings: 14kW up to 18kW
Output voltages: 0…20V up to 0…900V
Output currents: 0…20A up to 0…750A
Constant voltage and current regulation
3-digit LED display for voltage and current
U / I programmable via 0…10V
U / I monitoring via 0…10V
Remote ?on/off“ for DC output
Operation temp range 0-35°C (40°C on req.)
Mains input 3 x 400V +/-10% 50-60Hz, P.F. >0,95
Inrush current limit
Air cooling by fan, air volume req. max. 540m3/h
Stainless steel housing, for 19“ rack systems
DC output connection via copper bars
Options
Programming via PC (RS485/RS232/LAN)
Insulated analog amplifiers
Remote sensing
Regulation deviation <1%
Ripple (300 Hz) <1%
Model
Voltage (V)
Current (A)
Power (W)
EA-PS 1020-750
0-20
0-750
0-15000
EA-PS 1040-350
0-40
0-350
0-14000
EA-PS 1060-250
0-60
0-250
0-15000
EA-PS 1080-200
0-80
0-200
0-16000
EA-PS 1150-150
0-150
0-150
0-15000
EA-PS 1300-50
0-300
0-50
0-15000
EA-PS 1600-25
0-600
0-25
0-15000
EA-PS 1900-20
0-900
0-20
0-18000
DC Power Supplies PS 1000-40KW 30000W – 40000W
Key Features
High efficiency >85%
Output power ratings: 30kW up to 45kW
Output voltages: 0…20V up to 0…900V
Output currents: 0…50A up to 0…2000A
Constant voltage and current regulation
3-digit LED display for voltage and current
U / I programmable via 0…10V
U / I monitoring via 0…10V
Remote ?on/off“ for DC output
Operation temp range 0-35°C (40°C on req.)
Mains input 3 x 400V +/-10% 50-60Hz, P.F. >0,95
Inrush current limit
Air cooling by fan, air volume req. max. 1440m3/h
Stainless steel unit, built-in style
DC output connection via copper bars
Options
Programming via PC (RS485/RS232/LAN)
Insulated analog amplifiers
Remote sensing
Regulation deviation <1%
Ripple (300 Hz) <1%
Model
Voltage (V)
Current (A)
Power (W)
EA-PS 1020-2000
0-20
0-750
0-15000
EA-PS 1060-1000
0-40
0-350
0-14000
EA-PS 1060-6000
0-60
0-250
0-15000
EA-PS 1080-500
0-80
0-200
0-16000
EA-PS 1150-250
0-150
0-150
0-15000
EA-PS 1300-120
0-300
0-50
0-15000
EA-PS 1600-50
0-600
0-25
0-15000
EA-PS 1900-40
0-900
0-20
0-18000
DC Power Supplies PS 1000-20KW 18000W – 20000W
Key Features
High efficiency >85%
Output power ratings: 18kW up to 20kW
Output voltages: 0…20V up to 0…900V
Output currents: 0…20A up to 0…1000A
Constant voltage and current regulation
3-digit LED display for voltage and current
U / I programmable via 0…10V
U / I monitoring via 0…10V
Remote ?on/off“ for DC output
Operation temp range 0-35°C (40°C on req.)
Mains input 3 x 400V +/-10% 50-60Hz, P.F. >0,95
Inrush current limit
Air cooling by fan, air volume req. max. 1440m3/h
Stainless steel housing, for 19“ rack systems
DC output connection via copper bars
Parallel and series connection up to 30 units
Options
Programming via PC (RS485/RS232/LAN)
Insulated analogue amplifiers
Remote sensing
Regulation deviation <1%
Ripple (300 Hz) <1%
Model
Voltage (V)
Current (A)
Power (W)
EA-PS 1020-1000 WC
0-20
0-1000
0-20000
EA-PS 1040-500 WC
0-40
0-500
0-20000
EA-PS 1060-300 WC
0-60
0-300
0-18000
EA-PS 1080-250 WC
0-80
0-250
0-20000
EA-PS 1150-120 WC
0-150
0-120
0-18000
EA-PS 1300-60 WC
0-300
0-60
0-18000
EA-PS 1600-30 WC
0-600
0-30
0-18000
EA-PS 1900-20 WC
0-900
0-20
0-18000
DC Power Supplies PS 1000-40KW 36000W – 40000W
Key Features
High efficiency >85%
Output power ratings: 36kW up to 40kW
Output voltages: 0…20V up to 0…900V
Output currents: 0…40A up to 0…1000A
Constant voltage and current regulation
3-digit LED display for voltage and current
U / I programmable via 0…10V
U / I monitoring via 0…10V
Remote ?on/off“ for DC output
Operation temp range 0-35°C (40°C on req.)
Mains input 3 x 400V +/-10% 50-60Hz, P.F. >0,95
Soft start function
Water cooling, temperature controlled
Stainless steel unit IP53, for 19“ rack systems
DC output connection via copper bars
Parallel and series connection up to 30 units
Options
Programming via PC (RS485/RS232/LAN)
Insulated analogue amplifiers
Remote sensing
Regulation deviation <1%
Ripple (300 Hz) <1%
Model
Voltage (V)
Current (A)
Power (W)
EA-PS 1020-2000 WC
0-20
0-1000
0-20000
EA-PS 1040-1000 WC
0-40
0-500
0-20000
EA-PS 1060-600 WC
0-60
0-300
0-18000
EA-PS 1080-500 WC
0-80
0-250
0-20000
EA-PS 1150-250 WC
0-150
0-120
0-18000
EA-PS 1300-120 WC
0-300
0-60
0-18000
EA-PS 1600-60 WC
0-600
0-30
0-18000
EA-PS 1900-40 WC
0-900
0-20
0-18000
DC Power Supplies PS 1000-75KW 60000W – 80000W
Key Features
High efficiency >85%
Output power ratings: 60kW up to 80kW
Output voltages: 0…20V up to 0…900V
Output currents: 0…75A up to 0…3500A
Regulation deviation <2%, Ripple (300)Hz <2%
Constant voltage and current regulation
U / I programmable via 0…10V
U / I monitoring via 0…10V
Remote ?on/off“ for DC output
Operation temp range 0-35°C (40°C on req.)
Mains input 3 x 400V +/-10% 50-60Hz, P.F. >0,95
Inrush current limiter
Mains circuit breaker and mains power switch incl.
Air cooling (AC), Water cooling (WC)
Stainless steel unit IP53, for 19“ rack systems
Cabinet Rittal TS, RAL 7035 powder coated
Options
External LCD control unit EA-PS 280
Programming via PC (RS485/RS232/LAN)
Insulated analogue amplifiers
Remote sensing
Regulation deviation <1%
Ripple (300 Hz) <1%
Model
Voltage (V)
Current (A)
Power (W)
EA-PS 1020-3500 WC
0-20
0-3500
0-70000
EA-PS 1040-1700 WC
0-40
0-1700
0-68000
EA-PS 1060-1200 WC
0-60
0-1200
0-72000
EA-PS 1080-1000 WC
0-80
0-1000
0-80000
EA-PS 1150-500 WC
0-150
0-500
0-75000
EA-PS 1300-250 WC
0-300
0-250
0-75000
EA-PS 1600-100 WC
0-600
0-100
0-60000
EA-PS 1900-75 WC
0-900
0-75
0-67500
DC Power Supplies PS 1000-120KW 117000W – 120000W
Key Features
High efficiency >85%
Output power ratings: 117kW up to 120kW
Output voltages: 0…20V up to 0…900V
Output currents: 0…130A up to 0…60000A
Regulation deviation <2%, Ripple (300)Hz <2%
Constant voltage and current regulation
U / I programmable via 0…10V
U / I monitoring via 0…10V
Remote ?on/off“ for DC output
Operation temp range 0-35°C (40°C on req.)
Mains input 3 x 400V +/-10% 50-60Hz, P.F. >0,95
Inrush current limiter
Mains circuit breaker and mains power switch incl.
Air cooling (AC) or Water cooling (WC)
Cabinet Rittal TS, RAL 7035 powder coated
Options
External LCD control unit EA-PS 280
Programming via PC (RS485/RS232/LAN)
Insulated analogue amplifiers
Remote sensing
Regulation deviation <1%
Ripple (300 Hz) <1%
Model
Voltage (V)
Current (A)
Power (W)
EA-PS 1020-6000 WC
0-20
0-6000
0-120000
EA-PS 1040-3000 WC
0-40
0-3000
0-120000
EA-PS 1060-1200 WC
0-60
0-2000
0-120000
EA-PS 1080-1000 WC
0-80
0-1500
0-120000
EA-PS 1150-500 WC
0-150
0-800
0-120000
EA-PS 1300-250 WC
0-300
0-400
0-120000
EA-PS 1600-100 WC
0-600
0-200
0-120000
EA-PS 1900-75 WC
0-900
0-130
0-117000
SKU:
423