Category:Uncategorized
GV-Series – Static AC Voltage Source
Power Products
Static “AC” voltage sources GV series allow you to obtain a clean source of alternating voltage , isolated and totally independent from the load and line fluctuations. They are precision instruments designed for the stringent demands of development labs and for the flexibility of automatic and manual test equipment.
Functions of GV series:
- Sinusoidal or arbitrary output waveforms
- Output pfrequency from 40 to 200Hz in step 0,01Hz
- Timer from 1mS to ∞
- Max number of programmable steps 30
- Dips from 1mS
- UP and Down ramps
- Start angle settable from 0 to 360°
- Selectable trigger: line, auto and external
- Selectable phase after triggerr
- Loop function for all steps
- Report of measurement
- Amplifier operation (BOOSTER)
- PAUSE-RESUME
Measurements on display:
- Output voltage
- Output current
- Time
- Output power
- output cosφ and impedance parameter
Standard equipment:
- Keyboard
- Graphic display
- Encoder
- 8 programmable I/O
- RS232 / RS485 serial
- Booster input
- In/Out sync
- Power output up to250KVA+
Applications:
- Device supply with clean voltage or arbitrary waveform
- Supply of equipment with different frequency from line network
- Automatic test benches
- Electronic variac
300V-STANDARD MODEL:
Model | Power | Outuput 1 Vmax / Amax |
Output 2 Vmax / Imax |
GVC300-600VA | 600VA | 150V / 4A | 300V / 2A |
GVC300-1200VA | 1200VA | 150V / 8A | 300V / 4A |
GVC300-2500VA | 2500VA | 150V / 17A | 300V / 8,3A |
GVC300-5kVA | 5kVA | 150V / 33A | 300V / 17A |
GVC300-10kVA | 10kVA | 150V / 67A | 300V / 33A |
GVC300-15kVA | 15kVA | 150V / 100A | 300V / 50A |
GVC300-20kVA | 20kVA | 150V / 133A | 300V / 67A |
GVC300-30kVA | 30kVA | 150V / 200A | 300V / 100A |
GVC300-40kVA | 40kVA | 150V / 267A | 300V / 133A |
GVC300-50kVA | 50kVA | 150V / 333A | 300V / 167A |
GVC300-60kVA | 60kVA | 150V / 400A | 300V / 200A |
GVC300-80kVA | 80kVA | 150V / 533A | 300V / 267A |
GVC300-100kVA | 100kVA | 150V / 667A | 300V / 333A |
GVC300-120kVA | 120kVA | 150V / 800A | 300V / 400A |
GVC300-150kVA | 150kVA | 150V / 1000A | 300V / 500A |
500V-STANDARD MODEL:
Model | Power |
Output 1
|
Output 2 Vmax / Amax |
GVC-600VA | 600VA | 250V / 2,4A | 500V / 1,2A |
GVC-1200VA | 1200VA | 250V / 4,8A | 500V / 2,4A |
GVC-2500VA | 2500VA | 250V / 10A | 500V / 5A |
GVC-5kVA | 5kVA | 250V / 20A | 500V / 10A |
GVC-10kVA | 10kVA | 250V / 40A | 500V / 20A |
GVC-15kVA | 15kVA | 250V / 60A | 500V / 30A |
GVC-20kVA | 20kVA | 250V / 80A | 500V / 40A |
GVC-30kVA | 30kVA | 250V / 120A | 500V / 60A |
GVC-40kVA | 40kVA | 250V / 160A | 500V / 80A |
GVC-50kVA | 50kVA | 250V / 200A | 500V / 100A |
GVC-60kVA | 60kVA | 250V / 240A | 500V / 120A |
GVC-80kVA | 80kVA | 250V / 320A | 500V / 160A |
GVC-100kVA | 100kVA | 250V / 400A | 500V / 200A |
GVC-120kVA | 120kVA | 250V / 480A | 500V / 240A |
GVC-150kVA | 150kVA | 250V / 600A | 500V / 300A |