ISO 5151 HVAC testing and AC power requirements: PPS application note
This Pacific Power Source application note sets out the AC power requirements for testing non-ducted air conditioners and heat pumps to ISO 5151:2017. It is for HVAC manufacturers and compliance test labs.
Inside the note:
- Why a programmable AC source is used: galvanic isolation keeps grid disturbances and line noise away from the unit under test, and it can test at 50 Hz and 60 Hz
- The air enthalpy and balanced room-type calorimeter test set-ups, with the data collection period for each
- Test voltages from ISO 5151:2017 Table 2, including units with a wide or dual voltage rating
- Maximum cooling performance tests at 90% and 110% of nameplate voltage, and why to size the source for the low-line current of the largest unit
- Reporting requirements: voltage, frequency, current and power measured to better than 0.5% uncertainty, with the applied voltage held within 1.0% mean and 2.0% maximum
- Single-phase, split-phase and three-phase supply options
Applies to the ADF Series, AFX Series and LSX Series.
Download the application note below, or talk to us about your test set-up.