Testing PV micro-inverters with a four-quadrant AC source: PPS application note

Testing PV micro-inverters with a four-quadrant AC source: PPS application note

This Pacific Power Source application note explains how a four-quadrant linear AC power source can simulate the grid when testing grid-tied PV micro-inverters, which push current back into the source. It is for engineers developing or testing PV inverters.

Inside the note:

  • Test standards that apply to grid-tied PV inverters, including IEEE 1547, IEEE 1547.1, UL 1741 and IEC 61000-3-15
  • Why back-driving current into an AC source can shut it down, and how two-quadrant and four-quadrant operation differ
  • Regenerative and dissipative ways of absorbing reverse power
  • A test set-up using a 320LMX in split-phase mode, two micro-inverters and a parallel resistive load bank
  • Measured heat sink temperatures in source and sink mode; the note concludes the 320LMX can run continuously at about 25% of rated power when sinking current
  • Other benefits of a linear source here, such as no high-frequency switching noise on the output

Applies to the LMX Series.

Download the application note below, or talk to us about your test set-up.